
【国外标准】 Standard Practice for Testing Water Resistance of Coatings in 100 % Relative Humidity
本网站 发布时间:
2024-02-28
- ASTM D2247-15(2020)
- Active
选择类型:
电子版: 590元
/ 折扣价:
502 元
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
4.1 Water can cause the degradation of coatings, so knowledge of how a coating resists water is helpful for assessing how it will perform in actual service. Failure in tests at 100 % relative humidity may be caused by a number of factors including a deficiency in the coating itself, contamination of the substrate, or inadequate surface preparation. This practice is therefore useful for evaluating coatings alone or complete coating systems.4.2 Tests at 100 % relative humidity are used for specification acceptance, quality control, and research and development for coatings and substrate treatments. Some tests are used for a pass or fail determination at an arbitrary time. A coating system is considered to pass if there is no evidence of water-related failure after a period of time. Other tests are used to monitor degree of failure as a function of exposure time.4.2.1 Arbitrary pass/fail levels and the test durations required are typically set in other material specific test methods. Users of this practice alone may use the known performance of the controls to set test end points. Another option is to continue the test until all specimens have failed, and use the time to reach failure as a way to differentiate performance.4.3 Results obtained from the use of 100 % humidity tests in accordance with this practice should not be represented as being equivalent to a period of exposure to water in the natural environment, until the degree of quantitative correlation has been established for the coating or coating system.4.4 The test chamber can be a small laboratory cabinet or a room large enough to hold an automobile or a truck. Some automobile manufacturers test completed vehicles in rooms maintained at 100 % relative humidity. Corrosion tests can be conducted, as the condensate dripping off the test articles in not recirculated.1.1 This practice covers the basic principles and operating procedures for testing water resistance of coatings by exposing coated specimens in an atmosphere maintained at 100 % relative humidity so that condensation forms on all surfaces of test specimens.1.2 This practice uses the technique of creating a slight temperature differential within the exposure area to form condensation on the coated specimens. As the warmer saturated air passes the cooler specimens, water is deposited onto the specimens in the form of condensation.1.3 This practice places the entire specimen in the exposure area allowing condensation to form on all surfaces. This makes this practice suitable for flat panels as well as large or 3D objects. This practice differs from other methods where condensation is only formed on the front coating surface, while the back surface is outside the exposure area. Other tests may also deposit water droplets on the surface but where the source is not from condensation (for example, water spray).NOTE 1: Alternative practices for testing the water resistance of coatings include Practices D870, D1735, and D4585.1.4 This practice is limited to the methods of obtaining, measuring, and controlling the conditions and procedures of tests conducted in 100 % relative humidity. It does not specify specimen preparation, or evaluation of results.1.5 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM D2247-15(2020)
标准名称:
Standard Practice for Testing Water Resistance of Coatings in 100 % Relative Humidity
英文名称:
Standard Practice for Testing Water Resistance of Coatings in 100 % Relative Humidity标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- 国家标准计划
- BS EN 14625:2024 Ambient air. Standard method for the measurement of the concentration of ozone by ultraviolet
- BS EN 14626:2024 Ambient air. Standard method for the measurement of the concentration of carbon monoxide by non
- BS EN 14211:2024 Ambient air. Standard method for the measurement of the concentration of nitrogen dioxide
- BS EN 14212:2024 Ambient air. Standard method for the measurement of the concentration of sulphur dioxide
- 24/30506654 DC BS ISO 20038 Banking and related financial services — Key wrap using advanced encryption standard
- BS EN 4869-103:2024 Aerospace series. Expanded beam termini, fibre optic non-physical contact in EN 3645 standard
- BS EN 4869-104:2024 Aerospace series. Expanded beam termini, fibre optic non-physical contact in EN 3645 standard
- BS EN 4869-001:2024 Aerospace series. Expanded beam termini, fibre optic non-physical contact in EN 3645 standard
- BS EN 4869-101:2024 Aerospace series. Expanded beam termini, fibre optic non-physical contact in EN 3645 standard
- BS EN 4869-102:2024 Aerospace series. Expanded beam termini, fibre optic non-physical contact in EN 3645 standard
- BS ISO 27729:2024 - TC Tracked Changes. Information and documentation. International standard name identifier (ISNI)
- BS ISO 23603:2024 - TC Tracked Changes. Standard method of assessing the spectral quality of daylight simulators
- 24/30505086 DC BS EN IEC 61400-16 Standard file format for sharing power curve information
- BS ISO 27729:2024 Information and documentation. International standard name identifier (ISNI)
- 24/30504596 DC BS EN IEC 63147 Standard criteria for accident monitoring instrumentation for nuclear power